Lug Type Manual Operated Knife Gate Valve LTPZ73

Executive standard

Flange standard: GB/T 9113/ ANSI B16.5

Test and inspection: GB/ 13927/ ANSI 598

Performance range      

Pressure 1.0 1.6 150Lb MPa
Strength test 1.5 2.4 3.0
Sealing test 1.1 1.76 2.2
Suitable temperature PTFE≤200:Carbon steel≤425;

Stainless steel≤600:

Chrome-molybdenum-

vanadium steel≤600

°C
Medium Syrup, paper pulp, sewage, coal paste,lime-ash water etc.

Product Detail

Lug Type Manual Operated Knife Gate Valve Purpose

Mainly used for slag, bug dust, paper pulp, sewage, asphalt, grout etc. transporting pipelines in industrial, mining, environmental protection, food etc. trades, acting at connecting and closing the pipeline

Lug Type Manual Operated Knife Gate Valve Definition and Components


 What is a Lug Type Manual Operated Knife Gate Valve LTPZ73 and its main parts?

Lug Type Manual Operated Knife Gate Valve LTPZ73 is a specific design of knife gate valve featuring a lug-style body. This design has threaded inserts (lugs) on both sides of the valve body, allowing it to be bolted directly between two pipeline flanges using a dedicated set of bolts for each flange. This permits easy installation/removal and supports the valve in a dead-end service application. It is operated manually via a handwheel or lever.

Lug Type Manual Operated Knife Gate Valve Main Parts:

  • Lug Body: The valve body with protruding, threaded lugs for bolting between flanges.
  • Gate/Blade: A sharp, typically stainless steel plate that cuts through media to shut off flow.
  • Stem: A threaded, non-rising stem connected to the handwheel and gate.
  • Handwheel/Manual Actuator: The manual operator for opening/closing the valve.
  • Seats/Seal Rings: Resilient seals (e.g., EPDM, NBR) mounted in the body that the gate wedges against for tight shut-off. Often replaceable.
  • Packing Box/Gland: Seals around the stem to prevent leakage to the environment.
  • Bonnet/Yoke: Assembly that houses the stem and supports the handwheel.

Role, Characteristics, and Application Scenarios of Lug Type Manual Operated Knife Gate Valve in Pipelines


 Functions, Operational Features, Usage Scenarios, and Scenario Diagram

Functions: Provides reliable on/off isolation for moderately abrasive slurries, powders, granules, and viscous fluids. The lug design is ideal for systems requiring mid-line valve removal or dead-end service.

Water Valves Operational Features:

  • Manual Operation: Simple, direct control via handwheel. Requires physical effort depending on size/pressure.
  • Linear Cutting Action: The sharp gate cuts through thick media to achieve closure.
  • Lug Body Advantage: Allows installation using only bolts through the valve's lugs, without nuts on the valve side. This facilitates installation in tight spaces and permits the downstream side to be disconnected independently.
  • Bidirectional or Unidirectional Seal: Depending on seat design, it may seal from one direction or both.

Knife Gate Valve Usage Scenarios:

  • Slurry Handling (mining, wastewater sludge).
  • Powder & Bulk Solid Systems (cement, fly ash).
  • Pulp & Paper Stock Lines.
  • General Industrial On/Off Service where full bore flow and easy maintenance are needed.

Lug Type Manual Operated Knife Gate Valve Standards: Materials, Design, and Connections


Material, Design, and Connection Standards

Material Standards:

  • Body: ASTM A216 WCB (Carbon Steel), ASTM A351 CF8/CF8M (Stainless Steel).
  • Gate: 304/316 SS, often with hardened edge.
  • Seats: EPDM, NBR, UHMWPE, Viton®.
  • Stem: 304/316 SS.
  • Handwheel: Ductile Iron or Steel.
  • Design Standards: Commonly follows MSS SP-81 ("Knife Gate Valves - Flanged, Lug, Wafer, and Butt-welding Ends"). May also reference ISO 16136.
  • Connection Standards: The "Lug Type" is defined by MSS SP-81. The specific flange facing (e.g., RF, FF) and drilling pattern on the lugs typically conforms to common flange standards like:
  • ASME B16.5 (For Class 150/300)
  • EN 1092-1 (DIN) (For PN10/PN16)

How to Select Lug Type Manual Operated Knife Gate Valve


 How to Purchase

  • Define Requirements: Specify nominal size (DN/NPS), pressure rating (PN/Class), fluid media (including abrasiveness, % solids, temperature), and required seal material. Confirm that lug-type connection is suitable for your piping layout.
  • Source Suppliers: Identify reputable industrial valve manufacturers or distributors specializing in slurry/knife gate valves. Verify quality management certifications (ISO 9001).
  • Request Quotation & Data: Submit your specifications. Request a detailed quote including material specifications, torque values, and a dimensional drawing. For manual valves, inquire about the required number of turns/handwheel diameter for operation.
  • Evaluate & Place Order: Compare technical compliance, lead time, price, and warranty. Ensure the purchase order lists all critical specs: model (LTPZ73), size, pressure, materials, connection standard, and any special requirements.

Pre-Shipment Inspection for Export Lug Type Manual Operated Knife Gate Valve and Key Considerations


Pre-Export Inspection and Precautions

Inspection Protocol:

  • Visual & Dimensional: Check for damage, verify markings (size, pressure, material), and confirm lug dimensions/hole threading match the specified flange standard.
  • Material & Certificate Review: Cross-check provided material test reports (MTRs) against order requirements.
  • Functional Test: Operate the handwheel through full open/close cycles. Ensure smooth operation, no binding, and proper gate alignment.
  • Pressure Test: Witness shell (body) and seat leakage tests per API 598 or ISO 5208 standards. This is crucial for performance validation.
  • Packaging Check: Ensure valve interiors are protected (VCI bags, desiccant). Externally, valves should be securely mounted within sturdy, weather-resistant wooden crates suitable for shipping.

Precautions:

  • Ship in Closed Position: Protects the sealing edges of the gate and seat.
  • Protect Critical Surfaces: Coat exposed stems and flange/lug faces with anti-corrosive grease. Use protective covers on threaded lugs.
  • Secure Moving Parts: Ensure the handwheel is immobilized within the crate to prevent transit damage.
  • Complete Documentation: Pack manuals, test reports, packing lists, and certificates in a sealed plastic envelope inside the crate. Exterior markings must include gross weight, lifting points, and "Keep Dry" symbols.

Lug Type Manual Operated Knife Gate Valve Main part materials

Title of part Material
Body/Bonnet Carbon steel、Stainless steel
Gate Carbon steel、Stainless steel
Stem Stainless steel
Sealing face Rubber.PTFE,Stainless steel. Carbide alloy

Lug Type Manual Operated Knife Gate Valve Main dimensions(mm)

DN 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900
L 48 48 51 51 57 57 70 70 76 76 89 89 114 114 127 127 154
D PN10 165 185 200 220 250 285 340 395 445 505 565 615 670 780 895 1015 1115
PN16 165 185 200 220 250 285 340 405 460 520 580 640 715 840 910 1025 1125
150Lb 150 180 190 230 255 280 345 405 485 535 595 635 700 815
D1 PN10 125 145 160 180 210 240 295 350 400 460 515 565 620 725 840 950 1050
PN16 125 145 160 180 210 240 295 355 410 470 525 585 650 770 840 950 1050
150Lb 120.7 139.7 152.4 190.5 215.9 241.3 298.5 362 431.8 476.3 539.8 577.9 635 749.3
n-Фd PN10 4-18 8-18 8-18 8-18 8-18 8-22 8-22 12-22 12-22 16-22 16-26 20-26 20-26 20-30 24-30 24-33 28-33
PN16 4-18 4-18 8-18 8-18 8-18 8-22 12-22 12-26 12-26 16-26 16-30 20-30 20-33 20-36 24-36 24-39 28-39
150Lb 4-19 4-19 4-19 8-19 8-22 8-22 8-22 12-26 12-26 12-29 16-29 16-32 20-32 20-35

Note:1. Other specifications and flange standards are available upon request.

  1. Design and specifications are subject to change without prior notice.

    Leave Your Message




    ×

      Leave Your Message