Single Opening Air Valve QB1

Característica

Small in size, easy to install.

Parámetros de rendimiento                    

Nominal diameter: DN20~50mm

Presión nominal: PN1,6 MPa

Suitable temperature:s 80℃

Medio adecuado: Agua

Connection:Female screwed

Norma de ensayo: GB/T 13927

 Parte de Maine Materiales

Bonete- Hierro dúctil,

Calzo de goma

Asiento/bola flotante-Acero inoxidable

Cuerpo: hierro dúctil

Palanca-Acero inoxidable

Detalle del producto

Single Opening Air Valve Purpose

This valve is suitable for installation in high-rise building, factory, small pumping stations, water distribution, for air discharge tube and improve the systems of water conveyance efficiency and save energy.

Single Opening Air Valve Definition and Components


What is a Single Opening Air Valve QB1 and Its Main Parts?

En Single Opening Air Valve QB1 es un simplified combination air valve designed for basic air management in pipelines. Like the P41X, it performs dual functions through a single pipeline connection but typically has a less complex internal mechanism. The "QB1" designation is a common model series from manufacturers like GA Industries, APCO, or similar.

Componentes principales:

  • Unified Valve Body: A single, robust chamber with one main inlet connection. Simpler in design than high-end combination valves.
  • Integrated Float Mechanism: A single, dual-purpose float assembly that controls both air release and air intake functions through a common orifice or a simple two-stage mechanism.
  • Primary Orifice: A single opening that serves for both air discharge and intake, controlled by the float position.
  • Sealing System: Elastomeric seals or a poppet valve that closes when liquid is present.
  • Protective Screen/Cap: Prevents insect and debris ingress into the discharge port.

Role, Characteristics, and Application Scenarios of Single Opening Air Valve QB1 in Pipelines


Funciones, características operativas y escenarios de uso

Válvulas de agua Funciones en pipelines:

  • Basic Air Release: Vents air during system filling and small accumulations during operation.
  • Vacuum Protection: Admits air during pipeline drainage to prevent collapse.
  • Surge Mitigation: Helps dampen minor pressure surges by allowing rapid air intake.

Características operativas:

  • Simplified, Robust Design: Fewer moving parts than complex combination valves, leading to higher reliability in dirty water applications.
  • Single-Orifice Operation: The same physical opening is used for both air intake and discharge.
  • Economical Solution: Lower cost alternative to full-featured combination valves for less critical applications.
  • Maintenance-Friendly: Easier to service due to simpler internal components.

Escenarios de uso típicos:

  • Agricultural Irrigation Systems: On mainlines and laterals where cost is a major factor.
  • Small Water Distribution Networks: In rural or low-pressure systems.
  • Servicios de construcción: For basic air management in plumbing risers.
  • Low-Risk Industrial Applications: Where perfect air removal is not critical.
  • Sump Pump Discharge Lines: For basic air/vacuum management.

Válvula de aire de apertura simple

Normas para válvulas: Materiales, diseño y conexiones


Material, diseño y normas de conexión

Válvula de aire para agua Normas materiales:

  • Cuerpo: Cast Iron (ASTM A126 Class B), Ductile Iron (ASTM A536) with basic coating, or PVC for certain applications
  • Flota: Polypropylene or Polyethylene (less expensive than stainless steel).
  • Sellos: EPDM or Nitrile (standard)
  • Componentes internos: Stainless Steel or Brass for critical wear parts.

Normas de diseño y rendimiento:

  • Basic Performance: Generally follows AWWA C512 principles but may not have full certification.
  • Presión nominal: Typically PN10/PN16 (Class 125/150).
  • Industry Standards: May reference ISO 22149 or manufacturer-specific standards.
  • Simplified Testing: Often tested to basic performance criteria rather than full AWWA protocols.

Normas de conexión:

Threaded Connections (Most Common):

  • NPT: ½", ¾", 1", 1¼", 1½", 2" (ASME B1.20.1)
  • BSP: G½, G¾, G1, G1¼, G1½, G2
  • Conexiones embridadas: ASME B16.1 Class 125 for larger sizes (2" and up).
  • Discharge Port: Usually ½" or ¾" threaded with mesh screen

How to Select Single Opening Air Valve


 Proceso de contratación

Application Assessment:

  • Determine if basic QB1 valve is sufficient or if full combination valve (P41X) is needed
  • Fluido: Water, wastewater, mild chemicals
  • Pressure Range: Typically ≤ 150 psi (10 bar)
  • Gama de temperaturas: Usually -10°C to 60°C
  • Pipeline Size: Match valve size to pipe diameter (typically 1/4 to 1/2 of pipe size)

Technical Specifications:

  • Define required functions (air release, vacuum protection, or both)
  • Specify material requirements based on fluid compatibility
  • Determine connection type and size

Evaluación de proveedores:

  • Focus on manufacturers specializing in economical pipeline accessories
  • Request performance data and typical applications
  • Check for basic certifications and testing protocols

Quotation & Commercial Terms:

  • These are often stock items with short lead times (2-4 weeks)
  • Consider bulk pricing for multiple units
  • Clarify warranty terms (typically 1 year)

Requisitos de documentación:

  • Basic material certificates
  • Installation and maintenance instructions
  • Performance curves if available

Pre-Shipment Inspection for Export Single Opening Air Valve and Key Considerations

Functional Testing (Sample Basis - 5-10% of batch):

  • Basic Seal Test: Apply low air pressure (10-20 psi) to valve in closed position, check for leaks
  • Float Movement Test: Ensure float moves freely without binding
  • Orifice Check: Verify discharge port is clear and screen is intact

Consideraciones especiales:

  • These valves are often shipped in cantidades a granel - ensure uniform packing
  • For mixed shipments with other valves, pack QB1 valves separately
  • Consider humidity-controlled containers for long sea voyages
  • If valves include plastic floats, avoid extreme temperature exposure

By following this approach, you can successfully procure and export reliable Single Opening Air Valve QB1 units that provide essential, economical air management for basic pipeline systems.

Single Opening Air Valve Main dimensions(mm)

DN L L1 D D1 D2
20 120 15 105 75 56
25 120 15 115 85 65
32 120 15 140 100 76
40 120 15 150 110 84
50 120 15 165 125 99

Nota:1. Otras especificaciones y normas de brida disponibles bajo pedido.

  1. El diseño y las especificaciones están sujetos a cambios sin previo aviso.

    Deje su mensaje




    ×