Water Meter/Screwed End BSPT

Propósito

Measuring the volume of cold water passing through

the pipeline.

Característica

Dry type, magnetic drive, pointer-roller indicator.

easy and long term clear reading, freezing

resistance, long working life etc.

Estado de funcionamiento

Temperatura:<40℃

Presión: <1 MPa

Talla L B H Connecting

Thread

Peso

KG

15 165 98 104 G3/4B 1.2/1.3
20 190/195 98 106 G1B 1.3/1.4
25 260/225 103 112 G1 1/4 B 1.65/1.67
40 300/245 124 147 G2B 4/4

Detalle del producto

Water Meter/Screwed End BSPT Definition and Components


What is a Water Meter/Screwed End BSPT PN16 and its main parts?

Water Meter with Screwed End BSPT PN16 is a water volume measurement device designed for smaller pipeline diameters. It features British Standard Pipe Taper (BSPT) threaded connections at both ends, allowing for direct screw-in installation without flanges. The PN16 rating indicates it is designed for a maximum working pressure of 16 bar. It is compact, cost-effective, and widely used for end-user billing and monitoring.

Water Meter/Screwed End BSPT Main Parts:

  • Meter Body/Housing: The outer casing, typically made of bronze, brass, or cast iron, which houses the internal mechanism and features the male or female BSPT threads.
  • Measuring Chamber/Cartridge: The core unit where flow measurement occurs. Common types include:
  • Single-jet or Multi-jet Chamber: For velocity-based measurement.
  • Volumetric Chamber: For positive displacement measurement (e.g., oscillating piston, nutating disc).
  • Impeller/Turbine or Piston/Disc: The moving element driven by water flow.
  • Magnetic Coupling or Gear Train: Transmits the motion from the wet chamber to the dry register without direct contact, ensuring a watertight seal.
  • Register (Counter/Indicator): Displays the totalized water volume, usually in cubic meters (m³) or liters. Can be mechanical (number wheels) or electronic (LCD).
  • Threaded End Connections: Integral male (external) or female (internal) BSPT threads, sized according to standards (e.g., ½", ¾", 1").
  • Strainer/Sieve (Optional): Often integrated at the inlet to protect the mechanism from debris.

Role, Characteristics, and Application Scenarios of Water Meter/Screwed End BSPT in Pipelines


Funciones, características operativas, escenarios de uso y diagrama de escenarios

Funciones: To accurately measure, indicate, and totalize the volume of cold (or hot) potable water passing through a pipeline for billing, consumption monitoring, and leak detection.

Características operativas:

  • Direct Threaded Connection: Simple installation using pipe wrenches and sealant tape/paste.
  • Low Flow Sensitivity: Good accuracy at both low and high flow rates within its specified metering range (Q1 to Q4).
  • Low Pressure Loss: Designed to minimize restriction to flow.
  • Bidirectional Sealing (often): The threads and body seal can typically handle pressure from either direction.
  • Dry Dial/Dry Reader: The register is isolated from the water, preventing fogging and allowing for optional pulse output connections.
  • Escenarios de uso:
  • Residential Apartment/Individual Unit Metering.
  • Small Commercial Establishments (shops, restaurants, offices).
  • Submetering within a larger building or complex.
  • Industrial Process Lines with small water supply lines.
  • Agricultural or Garden Watering Points.Water Meter/Screwed End BSPT

Water Meter/Screwed End BSPT Standards: Materials, Design, and Connections


 Material, diseño y normas de conexión

Válvulas de suministro de agua Normas materiales:

  • Cuerpo: CW617N (Lead-free brass), Bronze (C83600/C84400), or Cast Iron.
  • Internal Mechanism: Plastics (Polysulfone, Noryl), Stainless Steel, Ceramic (for bearings).
  • Register Window: Polycarbonate or glass.

Normas de diseño:

  • Metrological: ISO 4064 (Water meters for cold potable water and hot water). Key parameters include accuracy class (e.g., Class 2), flow rates (Q1, Q2, Q3, Q4), and maximum permissible errors (MPEs).
  • Legal Metrology: For EU markets, compliance with the Measuring Instruments Directive (MID) and an active Type Examination Certificate are mandatory. OIML R49 is an international recommendation.
  • Presión nominal: PN16 por EN 12201 or similar standards.
  • Normas de conexión:
  • Rosca estándar: ISO 7-1 (BS 21) for BSPT (British Standard Pipe Taper) threads. The "T" denotes tapered threads which provide a pressure-tight seal.
  • Common Sizes: DN15 (½"), DN20 (¾"), DN25 (1")

How to Select Water Meter/Screwed End BSPT


 Cómo comprar Contador de agua

Define Technical Specifications:

  • Nominal Size (e.g., DN15, ½").
  • Fluid Type (Cold water <30°C / Hot water >30°C, up to a specified max, e.g., 90°C).
  • Required Accuracy Class (e.g., ISO 4064 Class 2).
  • Flow Rate Range (Q3 - Permanent Flow Rate) suitable for the application.
  • Required Certifications (MID for EU, OIML for other markets, local approvals like UKCA, NSF for potable water contact).
  • Register Type (mechanical, electronic with pulse output).
  • Identify Certified Suppliers: Source from manufacturers or distributors who can provide valid MID Type Examination Certificates or equivalent for the exact model. Check for ISO 9001 quality management certification.
  • Solicitar documentación técnica: Pídelo:
  • Detailed datasheet with metrological characteristics (Q1-Q4 values, accuracy curves).
  • Copia del Certificado de homologación (MID or other).
  • NSF/WRAS certificate of conformity for materials in contact with drinking water (if required).
  • Dimensional drawing and installation instructions.
  • Evaluar y ordenar: Compare offers based on certification validity, technical fit, price, and warranty. Ensure the purchase order references the exact model, certification numbers, and required test documentation.

Pre-Shipment Inspection for Export Water Meter/Screwed End BSPT and Key Considerations


Inspección y precauciones previas a la exportación

Protocolo de inspección:

  • Comprobación visual y de marcado: Verify clean casting, no defects. Check for permanent markings: size, PN16, Q3 value, accuracy class, manufacturer, model, year, MID "M" mark and notified body number (if applicable), flow direction arrow.
  • Dimensional & Thread Gauge Check: Verify thread size and taper using ring/plug gauges to ensure proper fit.
  • Metrological Performance Test (SAMPLING): Perform or witness a sample test on a calibrated water test bench according to ISO 4064. Check error at a minimum of three flow points (low, medium, high). Errors must be within the MPE for its class.
  • Prueba de presión: Subject meters to a hydrostatic pressure test (e.g., 2.4 MPa for PN16) to check for casing or seal leakage.
  • Prueba de funcionamiento: Check that the register advances smoothly and resets to zero correctly (for new meters). Test pulse output if applicable.
  • Inspección del embalaje: Individual boxes should protect the register glass and threads. Threads should have protective plastic caps.

Precauciones:

  • Legal Sealing: Garantizar la manufacturer's security seal is intact and unbroken. This is crucial for legal metrology integrity.
  • Proteger los hilos: Caps must be secure to prevent damage that could cause leaks during installation.
  • Avoid Moisture & Condensation: For electronic meters, ensure silica gel packets are in the packaging.
  • Documentación completa: Each shipment must include:
  • Certificado de conformidad stating compliance with relevant directives (MID).
  • Initial Verification Report (if the meter is pre-calibrated for the destination country).
  • Instruction manual in the required language.
  • Country-Specific Requirements: For some markets, initial verification must be performed by the destination country's metrology authority; in this case, meters are shipped without final sealing/verification. Clarify this requirement beforehand.

Water Meter/Screwed End BSPT Main dimensionsmm

Talla

(mm)

Q s

Max. Flow

QP

Nominal Flow

Qt

Transmitional

Flujo

Qmin

Caudal mínimo

Min.

Lectura

Max.

Lectura

m'/h L/h M'
15 3 1.5 150 60 0.0001 999999
20 5 2.5 250 100 0.001 999999
25 7 3.5 350 140 0.0001 999999
40 20 10 1000 400 0.001 999999

a) In the lower zonefrom Qmin inclusiveup to but excluding Qt is ± 5%.

b)In the upper zone from Qt inclusive up to and including Qs is cold potable water meter + 2%.

    Deje su mensaje




    ×

      Deje su mensaje